Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
1.
Dental press j. orthod. (Impr.) ; 25(1): 28-35, Jan.-Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1089830

ABSTRACT

ABSTRACT Objective: The purpose of this study was to evaluate the effect of the Yd:YAG laser irradiation on orthodontic bracket base surface. Shear bond strength (SBS) values and sites of the bonding failure interfaces were quantified. Methods: Brackets were divided into two groups: OP (One Piece - integral sandblast base) and OPL (One Piece - laser irradiation). The brackets were randomly bonded on an intact enamel surface of 40 bovine incisors. The SBS tests were carry out using a universal test machine. A stereomicroscopy was used to evaluate the adhesive remnant index (ARI), and surface characterization was performed by scanning electron microscopy (SEM). Student's t-test was used to compare the SBS between the two groups (p< 0.05). Frequencies and chi-square analysis were applied to evaluate the ARI scores. Results: OPL group showed higher value (p< 0.001) of SBS than OP group (43.95 MPa and 34.81 MPa, respectively). ARI showed significant difference (p< 0.001) between OPL group (ARI 0 = 100%) and OP group (ARI 0 = 15%). SEM showed a higher affinity between the adhesive and the irradiated laser base surface. Conclusions: Yd:YAG laser irradiation on bracket base increased SBS values, showing that bonding failure occurs at the enamel/adhesive interface. Laser-etched bracket base may be used instead of conventional bases in cases where higher adhesion is required, reducing bracket-bonding failure.


RESUMO Objetivo: O objetivo do presente estudo foi avaliar o efeito da aplicação do laser Yd:YAG sobre a superfície metálica da base de braquetes ortodônticos, a resistência da colagem ao cisalhamento (RU) e os locais das falhas nas interfaces adesivas. Métodos: Os braquetes foram divididos em dois grupos, de acordo com o tipo de base: OP (One Piece - monobloco, base jateada) e OPL (One Piece - monobloco, base irradiada a laser). Foram selecionados 40 incisivos bovinos hígidos para a colagem de braquetes na superfície do esmalte. Os testes de RU foram realizados por meio de uma máquina de ensaio universal EMIC DL1000. O Índice de Adesivo Remanescente (ARI) e a caracterização das superfícies foram realizados empregando-se estereomicroscópio e microscópio eletrônico de varredura (MEV). O teste t de Student foi aplicado para comparar a RU entre os dois grupos (p< 0,05). O ARI foi avaliado por meio da análise de Frequência e teste do Qui-quadrado. Resultados: O grupo OPL obteve maiores valores de RU (p<0,001) do que o grupo OP (43,95 MPa e 34,81 MPa, respectivamente), e o ARI obteve diferença significativa (p<0,001) entre os grupos OPL (ARI 0 = 100%) e OP (ARI 0 = 15%). A análise proveniente do MEV mostrou alta interação adesiva entre a resina e a superfície metálica da base irradiada pelo feixe de laser. Conclusões: A irradiação com laser Yd:YAG sobre a superfície da base de braquetes metálicos aumentou os valores da RU, demonstrando que as falhas adesivas ocorreram na interface esmalte/adesivo. O uso de braquetes modificados com irradiação a laser pode ser adotado como alternativa aos braquetes com bases convencionais nos casos em que uma maior retentividade for requerida para reduzir as falhas de adesividade.


Subject(s)
Humans , Animals , Dental Bonding , Orthodontic Brackets , Lasers, Solid-State , Surface Properties , Cattle , Shear Strength , Metals
2.
Innov. implant. j., biomater. esthet. (Impr.) ; 5(3): 13-18, set.-dez. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-588541

ABSTRACT

Neste trabalho de resistência à tração foi avaliada a eficiência de 4 agentes cimentantes (fosfato de zinco S. S. White, ionômero de vidro Ketac Cem Easymix, resina composta/ionômero de vidro RelyX Luting 2 e resina acrílica especial Panavia 21 TC) usados para fixar coroas totais de NiCr a munhões tronco-cônicos, usinados em liga de Ti-6Al-4V. Foram utilizados 40 munhões, distribuídos em grupos de 10, para cada material. Os ensaios mecânicos foram realizados em uma máquina universal MTS 810, na velocidade de 0,5 mm/min. A respectiva Análise de Variância (ANOVA) apontou existir diferença significante entre os grupos e o teste de Tukey (p < 0,05) também mostrou diferenças significantes entre eles, exceto nas comparações fosfato versus RelyX e fosfato versus Ketac Cem. O melhor desempenho foi apresentado pela resina Panavia 21 (1.127,996 N); a resina composta/ionômero de vidro RelyX (478,197 N) mostrou comportamento similar apenas ao do fosfato (430,662 N), o qual apresentou desempenho semelhante ao ionômero de vidro Ketac Cem (227,705 N).


In this work of tensile strength was evaluated the efficacy of 4 cements (S. S. White zinc phoshate, Ketac Cem Easymix glass ionomer, RelyX Luting 2 composite resin/glass ionomer and Panavia 21 TC special acrylic resin) used to fix NiCr crowns to usinated titanium alloy abutments. Were used 40 abutments distributed in groups of 10 elements, to each material. The mechanical essays were developed at a MTS 810 universal machine, adjusted to a 0.5 mm/m velocity. The ANOVA applied to data pointed out the existence of significant differences between groups; the subsequent Tukeyïs test (p<0.05) also detected significant differences, except at comparisons of phosphate versus RelyX and phosphate versus Ketac Cem. The better performance was presented by Panavia 21 (1,127.996 N); RelyX (478.197 N) showed itself similar only to phosphate (430.662 N), wich had a performance similar to that of Ketac Cem (227.705 N).


Subject(s)
Cementation , Dental Implants , Tensile Strength
3.
Innov. implant. j., biomater. esthet. (Impr.) ; 5(2): 35-39, maio-ago. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-581345

ABSTRACT

Por meio de tração, coroas totais de NiCr foram removidas de munhões pré-fabricados, compostos por uma liga de Ti6Al-4V. Num total de 20 munhões, 10 foram usados com sua superfície original e 10 com sua superfície modificada por laser, ambos cimentados com fosfato do zinco. O teste mecânico foi executado em uma máquina universal MTS 810 ajustada a uma velocidade de 0,5 mm/min. A análise estatística foi feita pelo teste de Levene, o qual mostrou homogeneidade de variâncias entre os grupos (F = 2,21; p < 0,1). O subsequente teste "t" de Student mostrou haver diferenças significantes entre os grupos. A modificação da superfície dos munhões através do laser causou um aumento na resistência à tração das coroas cimentadas com fosfato de zinco, de 430,66 para 1.514,87 N.


By means of tensile strength, NiCr total crowns were removed from machine-made conical abutments composed by an Ti-6Al-4V alloy. In a total of 20 abutments, 10 were used with it surface presenting high smoothness and 10 abutments had its surfaces modified by laser both cemented with zinc phosphate. The mechanical test was performed at a MTS 810 universal machine adjusted to a speed of 0.5 mm/m. The statistical analysis was done by Levene's test, which showed homogeneity of variances among groups (F =2.21; p < 0.1). "Student t test" showed that significant differences were found between groups. The modification of the abutment surface through laser caused an increase in pull-out resistance of crowns cemented with zinc phosphate from 430.66 N to 1.514,87 N.


Subject(s)
Cementation , Dental Implants , Tensile Strength
4.
ImplantNews ; 6(4): 381-385, 2009. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-544177

ABSTRACT

Implantes de Ti-cp foram irradiados utilizando-se feixe de laser Nd:YAG para serem comparados com implantes de superfície usinada. As amostras foram inseridas cirurgicamente na tíbia de coelhos. Após o período de oito semanas de cicatrização os animais foram sacrificados e os implantes retirados empregando-se teste de torque reverso. A análise por MEV-EDS da superfície irradiada com laser apresentou maior formação óssea em relação à superfície usinada. Ao teste de torque reverso o implante irradiado laser apresentou o valor de torque médio de 40 Ncm e o implante usinado 24 Ncm. Os resultados obtidos indicaram que a superfície irradiada por feixe de laser apresentou maior interação e adesão de tecido ósseo.


Ti-cp implants were irradiated using laser beam Nd:YAG to be compared with machined surface implants. The samples were inserted into rabbit tibia. After an eight-week healing period, the animals were sacrificed and the implants removed under reverse torque test. SEM-EDS analysis of the laser-irradiated surface showed higher bone formation than at the machined surface. The reverse torque test of the laser-irradiated implants showed medium torque values of 40 Ncm and machined implants of 24 Ncm. The results showed that the use of laser treatment imparts higher bone tissue interaction and adhesion.


Subject(s)
Animals , Rabbits , Biocompatible Materials , Dental Implants , Lasers , Titanium , Tibia
5.
Braz. oral res ; 23(2): 137-143, 2009. graf, tab
Article in English | LILACS | ID: lil-522293

ABSTRACT

The purpose of the present study was to evaluate, using a biomechanical test, the force needed to remove implants with surface modification by laser (Nd:YAG) in comparison with implants with machined surfaces. Twenty-four rabbits received one implant with each surface treatment in the tibia, machined surface (MS) and laser-modified surface (LMS). After 4, 8 and 12 weeks of healing, the removal torque was measured by a torque gauge. The surfaces studied were analyzed according to their topography, chemical composition and roughness. The average removal torque in each period was 23.28, 24.0 and 33.85 Ncm for MS, and 33.0, 39.87 and 54.57 Ncm for LMS, respectively. The difference between the surfaces in all periods of evaluation was statistically significant (p < 0.05). Surface characterization showed that a deep and regular topography was provided by the laser conditioning, with a great quantity of oxygen ions when compared to the MS. The surface micro-topography analysis showed a statistical difference (p < 0.01) between the roughness of the LMS (Ra = 1.38 ± 0.23 ìm) when compared to that of the MS (Ra = 0.33 ± 0.06 ìm). Based on these results, it was possible to conclude that the LMS implants' physical-chemical properties increased bone-implant interaction when compared to the MS implants.


Subject(s)
Animals , Rabbits , Dental Prosthesis Retention , Dental Implantation, Endosseous/methods , Implants, Experimental , Lasers, Solid-State/therapeutic use , Osseointegration/radiation effects , Titanium/chemistry , Ablation Techniques , Analysis of Variance , Biomechanical Phenomena , Microscopy, Electron, Scanning , Osseointegration/physiology , Surface Properties/radiation effects , Tibia , Time Factors , Torque , Titanium/radiation effects , Wound Healing/physiology , Wound Healing/radiation effects
6.
Acta odontol. venez ; 45(3): 359-362, 2007. ilus, tab, graf
Article in Spanish | LILACS | ID: lil-502093

ABSTRACT

El objetivo de este trabajo fue caracterizar y estudiar el efecto del tratamiento térmico hecho en una aleación metálica de cobre para el uso odontológico, con relación a su comportamiento frente a la corrosión, en un medio que simula la agresividad del ambiente bucal. La caracterización de la aleación fue hecha por medio de análisis de la composición química y microscopia óptica y los ensayos de corrosión comprendieran en la obtención de las curvas de polarización potenciostáticas en solución arenosa de ácido cítrico 1g/L. De acuerdo con los resultados obtenidos se observó que la aleación cuando sometida al tratamiento térmico, sufre una transformación de la estructura dendrítica para una estructura con fases bien definidas. En relación al proceso corrosivo, se verificó por medio de las curvas de polarización potenciostáticas que no ocurre pasivacíon, bien como no ha diferencia en la resistencia a la corrosión entre las muestras con y sin tratamiento térmico en el medio estudiado.


The aim of this work went characterize and to study the effect of heat treatment in based copper metallic alloy for application in dentistry, with relationship to its behavior before the corrosion, in a solution that simulates the aggressiveness of the oral environment. The characterization of the alloy was made by means of chemical analysis and optical microscopy and the corrosion tests consisted in obtaining the potentiostatic polarization curves, in acid citric solution 1g/L. Analyzing the obtained results it was observed that the alloy when submited to the thermal treatment there is a transformation of the dendritic structure for a phase granular structure. In relation to the corrosive process it was verified by means of potentiostatic polarization curves didn't happen passivation, as well as there were not differences in the resistance the corrosion between the samples with and without thermal treatment.


Subject(s)
Citric Acid/adverse effects , Dental Alloys/chemistry , Corrosion , Copper/chemistry , Brazil , Electrolysis/methods , Metallurgy , Microscopy/methods , Data Interpretation, Statistical
7.
Acta cir. bras ; 21(supl.4): 57-62, 2006. tab
Article in English | LILACS | ID: lil-440781

ABSTRACT

PURPOSE: The aim of this study was to analyse the surface of titanium implants using disc irradiated with lasers. METHODS: Titanium discs were irradiated with laser high insensitive (Nd-YAG), deposited durapatite and used thermal treatment. Sample received qualitative morphological analyse trough micrographics with many size in SEM (Scanning Electron Microscopy). RESULTS: Surface laser irradiation shows roughness and isomorphic characteristic. The durapatite amplified the titanium surface area by method biomimetic. CONCLUSION: The surface treatment presented more deposition of durapatite, roughness on the surface, better isomorphic characteristic and increase quantitative in titanium surface area, samples shows rugous, roughness and homogeneity there is not found in the implants available at the market.


OBJETIVO: Estudar a superfície de implantes osseointegráveis utilizando discos de titânio irradiados com feixe de laser. MÉTODOS: A amostra foi irradiada com feixes de laser de alta intensidade (Nd-YAG), posteriormente depositado hidróxiapatita e submetido a tratamento térmico. Foi analisada sob MEV (Microscópio Eletrônico de Varredura) e realizada análise morfológica qualitativa com microfotografias em vários aumentos. RESULTADOS: A superfície irradiada com laser apresentou deformidade superficial e característica isomórfica; a aplicação de hidroxiapatita pelo método de biomimético aumentou quantitativamente a área da superfície de titânio. CONCLUSÃO: A deposição de hidroxiapatita apresentou melhor característica isomórfica e aumento quantitativo da área superficial estudada, a amostra demonstrou características não encontradas nos implantes disposto no mercado.


Subject(s)
Biocompatible Materials , Durapatite , Dental Implants/standards , Lasers , Materials Testing , Titanium/radiation effects , Microscopy, Electron, Scanning , Surface Properties/radiation effects
8.
Rev. Assoc. Paul. Cir. Dent ; 57(5): 357-362, set.-out. 2003. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-391769

ABSTRACT

Investigou-se a resistência à corrosão de uniões soldadas da liga AuPd de aplicação odontológica antes e depois de serem submetidas ao processo de soldagem a laser e brasagem. Constatou-se que houve mudanças estruturais tanto na região da solda a laser como na brasagem, que apresentaram, respectivamente, microestrutura dendrítica refinada e granular grosseira. Os ensaios eletroquímicos em meio aerado de NaCl 0,15 mol L-1 à temperatura ambiente, que simula as condições do ambiente oral, demonstraram que a junta soldada a laser apresentou melhor resistência à corrosão quando comparada à brasagem e ao metal base


Subject(s)
Dental Soldering , Gold Alloys , Lasers , Methods
9.
Rev. Assoc. Paul. Cir. Dent ; 54(6): 470-5, nov.-dez. 2000. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-298148

ABSTRACT

Neste trabalho, foram investigadas as uniöes soldadas empregando brasagem e laser em uma liga odontológica de Au-Pd utilizada na confecçäo de próteses. Foram estudados os efeitos da energia de soldagem fornecida em cada processo sobre a microestrutura e a dureza, além de suas vantagens e desvantagens. Verificou-se que, na brasagem, o metal-base e o cordäo de solta apresentaram microestruturas distintas, e que na soldagem a laser foram identificadas três regiöes: o cordäo de solda, a zona afetada pelo calor (ZAC) e o metal-base. Devido ao feixe da solda a laser transferir uma menor energia ao metal-base, este minimizou o tamanho da ZAC - em conseqüência, näo deve causar distorçäo significativa nas peças protéticas, sendo, portanto, um processo adequado para a substituiçäo da brasagem neste tipo de aplicaçäo


Subject(s)
Dental Prosthesis , Dental Soldering , Gold Alloys , Lasers
10.
Rev. dent. press ortodon. ortop. maxilar ; 5(4): 72-6, jul.-ago. 2000. ilus
Article in Portuguese | LILACS, BBO | ID: lil-298075

ABSTRACT

O objetivo deste artigo é demonstrar aspectos relacionados às ligas ortodônticas (fios de níquel-titânio) e suas aplicaçöes clínicas adequadas. A movimetaçäo dentária produzida por essas ligas é considerada mais biológicas pelo fato de apresentarem o efeito conhecido como "memória de forma" e superelasticidade, isto é, na ativaçäo e desativaçäo permitem que ocorra uma grande deflexäo elástica, produzindo forças leves e constantes por um longo período de tempo


Subject(s)
Humans , Male , Female , Elasticity , Orthodontic Wires , Orthodontics , Tooth Movement Techniques
11.
Rev. odontol. UNESP ; 28(2): 429-39, jul.-dez. 1999. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-298427

ABSTRACT

O objetivo deste trabalho foi avaliar in vitro, através de microscopia eletrônica de varredura, a ocorrência e largura de fendas na parede axial de cavidades de classe V restauradas com resina composta (TPH) e diferentes sistemas adesivos (One-Step, Prime&Bond 2.0 e Scotchbond Multi-Purpose). Com base nos resultados, os autores puderam concluir que nenhum dos sistemas adesivos utilizados foi capaz de prevenir completamente a ocorrência de fendas axiais, e o material que apresentou melhores resultados foi o One-Step, seguido por Prime&Bond 2.0 e Scotchbond Multi-Purpose, que apresentaram comportamentos semelhantes entre si


Subject(s)
Composite Resins , Dentin-Bonding Agents , Microscopy, Electron, Scanning
12.
PILARES ; 3(7): 7-9, 17-9, nov. 1999. ilus, tab
Article in Spanish | LILACS | ID: lil-289176

ABSTRACT

Se evaluó la microestructura y la dureza de las aleaciones odontológicas utilizadas en prótesis sobre implanttes soldadas con laser. Los materiales utilizados fueron titanio comercialmente puro, una aleación de plata-paladio y una aleación de oro-paladio. Se verificó que en las soldaduras con laser la microestructura de las aleaciones presentaba tres regiones distintas: una hilera de soldadura, la zona afectada por el calor - (ZAC) y un metal base. El Ti (comercialmente puro) presentó una microestructura con una hilera de soldadura más refinada y de mayor dureza que un metal base y uno ZAC. Se observaron en las aleaciones AG-Pd y Au-Pd la aparición de una estructura dendrítica en la hilera de soldadura, siendo la dureza de éste menor que la del metal base y uno ZAC. Las microestructuras y la dureza fueron acordes con las altas velocidades de enfriamiento obtenidas durante la soldadura. En las tres aleaciones la ZAC fue pequeña comparado con otros procesos de soldadura, como uno convencional


Subject(s)
Dental Alloys/chemistry , Dental Soldering , Dental Implantation, Endosseous/methods , Lasers , Hardness/radiation effects , Microscopy, Electron, Scanning/methods , Palladium/chemistry , Dental Prosthesis, Implant-Supported/standards , Silver/chemistry , Surface Properties , Titanium/chemistry
13.
BCI ; 6(2): 34-40, abr.-jun. 1999. ilus
Article in Portuguese | LILACS, BBO | ID: lil-256208

ABSTRACT

Três implantes dentais de titânio disponíveis no Brasil foram analisados neste estudo. O objetivo desta análise foi avaliar a topografia superficial e a interface implante-conector protético usando para isso microscopia eletrônica de varredura (MEV). Os resultados obtidos com MEV näo mostraram diferenças significantes entre os diferentes implantes analisados, exceto para o jateado, o qual apresentou uma superfície mais irregular. As superfícies de todas as amostras mostraram um contorno homogêneo, mas apresentaram-se cobertos por contaminantes e irregularidades, sugerindo que esses contaminantes näo correspondiam à corpos estranhos aderidos mas pertenciam a própria superfície, demonstrando provavelmente falta de controle de qualidade na usinagem dos mesmos. A análise da interface implante-conector protético variou de acordo com o implante, mas de uma forma geral, todas as amostras apresentaram uma boa adaptaçäo entre os componentes. Podemos concluir que todos os implantes analisados apresentaram, de uma forma geral com uma boa qualidade e dentro dos padröes encontrados no mercado


Subject(s)
Dental Implantation, Endosseous , Osseointegration
14.
JBC j. bras. clin. estet. odontol ; 3(15): 38-41, maio 1999. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-415760

ABSTRACT

Três implantes dentais de titânio disponíveis no Brasil foram analisados neste trabalho. O objetivo do estudo foi avaliar a composição metalográfica, usando para isso microscopia óptica e microscopica eletrônica de varredura (MEV) e a análise da composição química, através de espectroscopia por dispersão de energia (EDS) e espectrometria de emissão atômica. A análise metalográfica mostrou que todos os implantes analisados apresentavam uma estrutura de fase α+β, típica para titânio comercialmente puro, tido como material ideal para implantes dentais. A espectrometria por emissão atômica mostrou uma composição química semelhante entre as amostras (titânio e menos de 0,5% de outros elementos, como oferro, por exemplo). Já a EDS mostrou uma composição predominante d titânio, reforçando os resultados da análise anterior


Subject(s)
Dental Implantation, Endosseous , In Vitro Techniques , Aluminum , Chemical Phenomena , Iron , Microscopy, Electron, Scanning , Titanium , Vanadium
15.
Rev. odontol. UNESP ; 27(2): 417-25, jul.-dez. 1998. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-250903

ABSTRACT

O objetivo deste trabalho foi caracterizar e estudar o efeito do tratamento térmico efetuado numa liga metálica à base de cobre para uso odontológico, com relaçäo a seu comportamento ante a corrosäo, em um meio que simula a agressividade do ambiente bucal. A caracterizaçäo da liga foi feita por meio da análise da composiçäo química e de microscopia óptica, e os ensaios de corrosäo compreenderam a obtençäo das curvas de polarizaçäo potenciostáticas em soluçäo aerada de ácido cítrico 1 g/L. De acordo com os resultados obtidos, observou-se que a liga, quando submetida ao tratamento térmico, sofre transformaçäo de uma estrutura dendrítica para uma estrutura com fases bem definidas. Em relaçäo ao processo corrosivo, verificou-se, por meio das curvas de polarizaçäo potenciostáticas, que näo ocorre passivaçäo, bem como näo há diferença na resistência à corrosäo entre as amostras com e sem tratamento térmico no meio estudado


Subject(s)
Corrosion , Dental Alloys
16.
Rev. odontol. UNESP ; 27(1): 151-63, jan.-jun. 1998. tab
Article in Portuguese | LILACS, BBO | ID: lil-250883

ABSTRACT

Em razäo do aparecimento no comércio odontológico de uma grande quantidade de ligas metálicas näo-cobres como alternativa à utilizaçäo de ligas à base de ouro, este trabalho tem como objetivo avaliar a propriedade física de dureza superficial pelo método Vickers em funçäo de diferentes tratamentos térmicos, em cinco ligas metálicas à base de cobre, duas comerciais [Duracast M.S. e Goldent L.A.] e três experimentais, denominadas CuBe1, CuBe2 e CuBeCo5. A dureza das ligas pesquisadas foi determinada em três tratamentos distintos, ou seja: sem tratamento térmico (bruto de fundiçäo), TT1 (aquecimento das amostras a 850ºC, por 1,2 e 3 horas, seguindo de resfriamento lento), e no tratamento TT2 (reaquecimento das amostras a 325ºC, por 1,2 ou 3 horas, seguido de resfriamento rápido ou resfriamento lento). De posse dos resultados obtidos e com base na análise estatística realizada, foi possível concluir que: os tratamento térmicos provocaram influência nas ligas pesquisadas; o resfriamento rápido provocou maior dureza nas ligas do que o resfriamento lento; o tratamento TT2, de maneira geral, aumentou a dureza Vickers média obtida durante o TT1, e quanto maior o período de aquecimento (1,2 e 3 horas) maior foi a dureza Vickers média obtida, na maior parte dos experimentos


Subject(s)
Hardness , Dental Alloys/analysis , Thermic Treatment
17.
Rev. odontol. UNESP ; 27(1): 165-73, jan.-jun. 1998. tab
Article in Portuguese | LILACS, BBO | ID: lil-250884

ABSTRACT

Avaliou-se neste trabalho a resistência à corrosäo de cinco ligas metálicas à base de cobre, sendo duas comerciais, Duracast e Goldent, e três experimentais, CuBe1, CuBe2 e MID1 em funçäo de tratamentos térmicos aplicados. Os corpos-de-prova foram obtidos por fundiçäo odontológica de precisäo e tratados termicamente, em duas condiçöes distintas: bruto de fundiçäo (T1). Para os testes de resistência à corrosäo por imersäo contínua, foram utilizados dois meios que simulam agentes agressivos da cavidade bucal: saliva artificial e sulfeto de sódio a 1 por cento. Os ensaios de corrosäo foram realizados nos tempos de 1, 24 e 48 horas, 7 e 15 dias, sendo fixados, para a sua avaliaçäo, níveis de oxidaçäo e corrosäo numa escala de 0 a 7. De posse dos resultados, foi possível concluir que: a liga MID1 apresentou melhor resistência à corrosäo, tanto em saliva artificial como em soluçäo de sulfeto de sódio a 1 por cento; o tratamento térmico (T1) melhorou o comportamento da liga MID1, especialmente quando imersa em soluçäo de sulfeto de sódio


Subject(s)
Acid Etching, Dental , Corrosion , Dental Alloys/analysis , Thermic Treatment
18.
Rev. odontol. UNESP ; 23(2): 261-9, jul.-dez. 1994. ilus
Article in Portuguese | LILACS, BBO | ID: lil-143454

ABSTRACT

O fio de aço inoxidável 316L, reto ou deformado por torçäo, foi analisado através de microscopia eletrônica de varredura (MEV) e metalografia. A torçäo aumentou as linhas de segregaçäo, deformou a superfície e gerou tensäo na estrutura interna do metal. Após 120 dias de implantaçäo no tecido muscular de rato, o fio reto apresentou fendas rasas, e no torcido observaram-se fendas profundas, sugestivas de processo corrosivo. Estes resultados mostraram que o fio 316L sofre modificaçöes após a torçäo, que säo acentuadas com a implantaçäo. Períodos mais longos de observaçäo säo necessários para melhor avaliar as alteraçöes do fio 316L, particularmente corrosäo provocadas pela implantaçäo


Subject(s)
Animals , Rats , Stainless Steel/therapeutic use , Bone Wires/classification , Metals/therapeutic use , Corrosion , Microscopy, Electron, Scanning/methods
19.
Rev. odontol. Univ. Säo Paulo ; 4(4): 304-8, out.-dez. 1990. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-858632

ABSTRACT

Procurou-se caracterizar as fases presentes numa liga metálica à base de cobre do sistema Cu-Zn-Al-Ni, aplicada a Odontologia, e relacioná-las com outras propriedades. A caracterização foi feita após fundição odontológica, na sua estrutura bruta de fusão e após tratamentos térmicos. Com o objetivo de obter-se melhor resistência à corrosão, relacionada com mudanças estruturais no estado sólido, submeteu-se a liga diferentes tempos de recozimento a saber: 30, 45 e 60 minutos nas seguintes temperaturas: 750ºC, 800ºC e 850ºC e analisou-se as fases presentes por meio de difração de raios-X e microscopia eletrônica de varredura (M.E.V.). Os resultados mostram, após o tratamento térmico, o aparecimento de uma fase, provavelmente Cu3Al, que parece ser a responsável pela sensível melhora na resistência à corrosão em relação ao estado bruto de fusão


Subject(s)
Aluminum , Copper , Dental Alloys , Dental Casting Technique , Nickel , Zinc
20.
Rev. odontol. Univ. Säo Paulo ; 3(3): 408-13, jul.-set. 1989. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-98628

ABSTRACT

Foram estudadas 10 ligas alternativas desenvolvidas no Departamento de Dentística da Faculdade de Odontologia de Bauru quanto à contraçäo de fundiçäo pelo método de COLEMAN e EARNSHAW e comparadas com liga de ouro tipo III e IV e ligas alternativas encontradas no comércio


Subject(s)
Copper , Dental Casting Investment , Dental Alloys
SELECTION OF CITATIONS
SEARCH DETAIL